Galvanic Corrosion & Stray Current Testing in Long Beach

Zincs gone in weeks, pitted props, a flaking outdrive? Reference-electrode testing finds out whether it's galvanic corrosion or stray current, then fixes it.

Last updated:

Long Beach Marine Electric connects boat owners with licensed, insured marine electricians for galvanic corrosion testing and stray current diagnosis: measuring hull potential with a silver/silver chloride reference electrode, finding leakage on board, and installing galvanic isolators or isolation transformers. In a crowded marina, boats are connected to each other through the shore-power safety ground, so a neighbor's problem can eat your zincs. Testing tells you whose problem it is.

What happens on the first visit

  1. Hull potential readings with a silver/silver chloride reference electrode, with shore power connected and disconnected, to separate a marina-side problem from an on-board one.
  2. Check of the bonding system: continuity from each underwater metal (shaft, strut, rudder, through-hulls, outdrive) to the anodes.
  3. Leakage-current test of the boat's DC and AC systems. A small DC leak to a bonded fitting is classic stray-current corrosion.
  4. Anode condition and type check: zinc, aluminum or magnesium suited to salt water and to your underwater metals.
  5. A written finding and options: anode changes, bonding repair, a galvanic isolator or an isolation transformer, each with a price.

Galvanic corrosion vs stray current

Galvanic corrosion happens when two different metals are connected and immersed in the same seawater. The less noble metal corrodes to protect the more noble one. That's what sacrificial anodes are for. Connected to shore power, every boat's underwater metal is also tied to every other boat's through the green safety ground, so a dock of boats becomes one big galvanic circuit.

Stray current corrosion is faster and worse: DC current leaking from a wiring fault, on your boat or nearby, leaves through an underwater fitting and takes metal with it. It can destroy anodes, props and outdrive legs in weeks rather than seasons. The symptoms look similar from the dock, so measurement is the only way to tell them apart.

What a reference-electrode test tells you

A silver/silver chloride reference electrode lowered into the water next to the hull measures the boat's corrosion potential in millivolts. The working rule from cathodic-protection practice is that adequate protection shifts a metal's potential at least 200 mV more negative than its natural resting voltage. Aluminum is the special case: it rests around -760 mV in seawater, needs about -900 to -950 mV for protection, and shouldn't be driven past about -1,100 mV, where overprotection blisters paint and damages the metal. That's why an aluminum outdrive needs the right anode, not just more of them.

Taking readings with shore power on and off, and with on-board breakers switched one at a time, shows whether the problem comes in through the shore cord or starts on board.

Galvanic isolator or isolation transformer?

A galvanic isolator sits in the shore-power ground and blocks the low-voltage galvanic currents between boats while still passing fault current to keep the ground safe. A fail-safe, ABYC A-28-compliant unit such as the ProMariner ProSafeFS lists at about $605 before installation. An isolation transformer breaks the direct connection to shore power entirely. It's the stronger fix, also removes the need for an onboard ELCI if mounted within 10 feet of the inlet, and is common on larger yachts, but it's heavier and costs more. Read galvanic isolator vs isolation transformer for the full decision.

Insurance, warranty and who pays

Corrosion testing and isolator installation are owner-paid. Corrosion damage itself is usually treated by insurers as wear, not a covered loss, which is why catching it early with a test is cheaper than replacing an outdrive. Testing typically takes one to two hours at the slip. Anode replacement on shafts and struts waits for a haul-out or a diver.

What's included

  • Hull potential readings (shore power on/off)
  • Bonding system continuity check
  • DC and AC leakage testing
  • Anode type and condition assessment
  • Galvanic isolator installation
  • Isolation transformer assessment
  • Bonding repair
  • Written readings and recommendations

DIY vs cheap fix vs proper corrosion work

Factor DIY Cheap operator Proper marine work
Diagnosis Look at the zincs Replace zincs Reference-electrode readings, power on and off
Anodes More is better Whatever fits Right metal and size for the readings
Bonding Not checked Not checked Continuity verified to every fitting
Shore-power path Ignored Ignored Isolator or transformer where needed
Result Zincs gone again Damage continues Protected range confirmed by measurement

Related resources

Sources

How it works

How galvanic corrosion testing works

  1. 01

    Tell us what's corroding

    Zincs, props, outdrive or through-hulls, and how fast. You get a callback the same day.

  2. 02

    Measure

    Reference-electrode readings with shore power on and off, plus bonding and leakage checks.

  3. 03

    Fixed price

    A written price for the fix: bonding repair, anodes, isolator or transformer.

  4. 04

    Re-measure

    Readings are taken again after the work to confirm the hull is in the protected range.

Get galvanic corrosion testing at your slip today

Same-day callback. Written price before any work.

Straight answers

Galvanic Corrosion Testing questions

Why are my zincs disappearing so fast?

Either they're doing their job against a large galvanic load (common in crowded marinas through the shore-power ground), or stray DC current is leaking from a wiring fault on your boat or a neighbor's. A reference-electrode test with shore power on and off tells you which.

Can my neighbor's boat corrode mine?

Yes. Boats connected to the same shore-power system share the safety ground, which links their underwater metals. A boat with poor protection or a fault can drain your anodes. A galvanic isolator or isolation transformer breaks that link.

Do I need more zincs?

Not necessarily. More anode surface can overprotect some metals, especially aluminum outdrives, which shouldn't be driven past about -1,100 mV. The right answer comes from measuring hull potential, not adding anodes.

Can this be tested without hauling the boat?

Yes. Reference-electrode readings, bonding checks and leakage tests are all done at the slip. Replacing shaft or strut anodes needs a diver or a haul-out.

Who does the work, and how do I know they’re qualified?

Long Beach Marine Electric is a free service that connects you with an independent, licensed and insured marine electrician who holds the American Boat & Yacht Council (ABYC) Marine Electrical Certification. Ask your electrician for proof of license and insurance before work starts.

Find out what's eating your zincs

Call (562) 374-7233 · Same-day callback